ABB ACH580 HVAC & ACQ580 Water/Wastewater Frequency Inverters
The ABB ACH580 and ACQ580 Drive Series (featured model: ACH580-01-045A-4 22 kW & ACQ580-01-045A-4 22 kW) represent ABB's industry-dedicated variable frequency drive platforms, engineered specifically for building infrastructure, HVAC systems, municipal water supply, and wastewater treatment plants. Featuring **native BACnet MS/TP, Modbus RTU, and N2** building automation protocols, the **ACH580** delivers effortless control over supply fans, return fans, cooling towers, and chillers with override fire mode and resonance frequency elimination. The **ACQ580** incorporates specialized water application algorithms, including multi-pump cascade control, sensorless flow calculation, soft pipe fill to prevent water hammer, and anti-ragging pump cleaning cycles. Covering power ratings from 0.75 kW to 500 kW across 3-phase 208V to 480V mains (R1 to R11 frame sizes), ACH580 and ACQ580 inverters feature integrated **chokes for low harmonics** and **Safe Torque Off (STO SIL3/PL e)**, serving as the direct 1-to-1 modernized replacement for legacy **ABB ACH550** and **ACS550** drives.
Technical Specifications
| Featured Model | ACH580-01-045A-4 / ACQ580-01-045A-4 (22 kW, 45A, 380V-480V, Wall-Mounted R4 Frame) |
|---|---|
| Brand / Manufacturer | ABB (Motion Drive Division) |
| Product Series | ACH580 Series (HVAC Dedicated) & ACQ580 Series (Water/Wastewater Dedicated) |
| Power Range Covered | 0.75 kW to 500 kW (1.0 HP to 700 HP) across Wall-Mounted (-01) & Cabinet (-04/-07) |
| Mains Voltage Supply | 3-Phase 208V to 240V AC / 3-Phase 380V to 480V AC (50/60 Hz) |
| Embedded Automation Protocols | ACH580: BACnet MS/TP, Modbus RTU, N2 / ACQ580: Modbus RTU, PROFIBUS, PROFINET, Modbus TCP |
| Functional Safety & Harmonics | STO (Safe Torque Off SIL3 / PL e), Integrated Swinging Choke for Low Harmonic Distortion |
| Enclosure Protection Rating | IP21 / UL Type 1 Standard (IP55 / UL Type 12 Washdown Enclosure Optional) |
Documentation & Resources
ABB ACH580 & ACQ580 Drive Power Rating & Frame Size Matrix
Complete selection matrix for ABB ACH580 HVAC and ACQ580 Water drives. Review rated motor power, output current, frame size, and standard model numbers:
| Mains Voltage (3-Phase) | Motor Power (kW) | Nominal Current (A) | ACH580 Model (HVAC) | ACQ580 Model (Water) | Frame Size |
|---|---|---|---|---|---|
| 380V - 480V AC | 0.75 kW | 2.6 A | ACH580-01-02A7-4 | ACQ580-01-02A7-4 | R1 Frame |
| 380V - 480V AC | 1.5 kW | 4.0 A | ACH580-01-04A1-4 | ACQ580-01-04A1-4 | R1 Frame |
| 380V - 480V AC | 3.0 kW | 7.2 A | ACH580-01-07A3-4 | ACQ580-01-07A3-4 | R1 Frame |
| 380V - 480V AC | 5.5 kW | 12.6 A | ACH580-01-012A-4 | ACQ580-01-012A-4 | R2 Frame |
| 380V - 480V AC | 11.0 kW | 25.0 A | ACH580-01-026A-4 | ACQ580-01-026A-4 | R3 Frame |
| 380V - 480V AC | 22.0 kW | 45.0 A | ACH580-01-045A-4 | ACQ580-01-045A-4 | R4 Frame |
| 380V - 480V AC | 45.0 kW | 88.0 A | ACH580-01-088A-4 | ACQ580-01-088A-4 | R5 Frame |
| 380V - 480V AC | 75.0 kW | 145.0 A | ACH580-01-145A-4 | ACQ580-01-145A-4 | R6 Frame |
| 380V - 480V Heavy | 110 kW - 500 kW | 206 A - 910 A | ACH580-01 / ACH580-04... | ACQ580-01 / ACQ580-04... | R7 to R11 Frame |
Legacy ABB ACH550 / ACS550 to ACH580 & ACQ580 Upgrade Guide
Obsolete ABB ACH550 HVAC inverters and ACS550 general purpose drives can be directly upgraded to current ACH580 or ACQ580 drives with 100% mechanical and electrical alignment:
| Legacy ABB Inverter Code (Obsolete) | Legacy Drive Power & Current | Current ACH580 / ACQ580 Equivalent | Key Functional & Efficiency Upgrades |
|---|---|---|---|
| ACH550-UH-03A3-4 / ACH550-01-03A3-4 | 1.1 kW / 3.3 A 400V | ACH580-01-04A1-4 / ACQ580-01-04A1-4 100% Drop-In | Native BACnet MS/TP, intuitive graphic display, bluetooth panel configuration option. |
| ACH550-UH-012A-4 / ACS550-01-012A-4 | 5.5 kW / 12 A 400V | ACH580-01-012A-4 / ACQ580-01-012A-4 100% Drop-In | Identical mounting hole centers, integrated STO SIL3/PL e, lower harmonic distortion. |
| ACH550-UH-023A-4 / ACS550-01-023A-4 | 11.0 kW / 23 A 400V | ACH580-01-026A-4 / ACQ580-01-026A-4 100% Drop-In | Enhanced motor control (supports IE3/IE4/IE5 SynRM motors), soft pipe fill algorithm. |
| ACH550-UH-045A-4 / ACS550-01-045A-4 | 22.0 kW / 45 A 400V | ACH580-01-045A-4 / ACQ580-01-045A-4 100% Drop-In | Direct drop-in replacement for AHU fans, chiller pumps, and municipal booster pumps. |
Expert Technical Sourcing & System Integration Notes
When replacing older ABB ACH550 or ACS550 inverters in building automation systems or water treatment plants, switching to current ACH580 and ACQ580 drives provides instant energy savings, reduced harmonic distortion, embedded pump clean cycles, and seamless BACnet/Modbus integration. Simply supply us with your existing drive nameplate code or serial number (e.g., ACH550-UH-045A-4 or ACQ580-01-045A-4), and our technical engineering team will deliver a 100% compliant replacement specification and proposal.
Core Benchmark Model Standard Configurations
- ACH580-01-02A7-4 (0.75 kW HVAC)
- ACH580-01-04A1-4 (1.5 kW HVAC)
- ACH580-01-07A3-4 (3.0 kW HVAC)
- ACH580-01-012A-4 (5.5 kW HVAC)
- ACH580-01-026A-4 (11.0 kW HVAC)
- ACH580-01-045A-4 (22.0 kW HVAC)
- ACH580-01-088A-4 (45.0 kW HVAC)
- ACH580-01-145A-4 (75.0 kW HVAC)
- ACQ580-01-02A7-4 (0.75 kW Water)
- ACQ580-01-04A1-4 (1.5 kW Water)
- ACQ580-01-07A3-4 (3.0 kW Water)
- ACQ580-01-012A-4 (5.5 kW Water)
- ACQ580-01-026A-4 (11.0 kW Water)
- ACQ580-01-045A-4 (22.0 kW Water)
- ACQ580-01-088A-4 (45.0 kW Water)
- ABB ACH550-UH-012A-4 Replacement
- ABB ACH550-UH-023A-4 Replacement
- ABB ACH550-UH-045A-4 Replacement
- ABB ACH580 Bluetooth Assistant Panel
- ABB ACQ580 Pump Clean Anti-Ragging Drive