SEW R67DRN100L4 Helical Inline Gearmotor
The SEW R67DRN100L4 is a robust, highly versatile inline helical gearmotor engineered for medium-to-heavy industrial applications requiring high mechanical power density, durable thermal stability, and long operating service life[cite: 21]. Featuring versatile mounting styles (foot-mounted R67/RX87, B5/B14 flange RF67/RXF87, and solid shaft)[cite: 21], it is widely deployed across conveyor systems, packaging machinery, chemical mixing, and automated production machinery[cite: 21].
Technical Specifications
| Model / Part Number | R67DRN100L4[cite: 21] |
|---|---|
| Brand / Manufacturer | SEW-Eurodrive[cite: 21] |
| Gear Unit Type | R Series (Helical Gear Unit, Inline Output Shaft)[cite: 21] |
| Motor Type | DRN100L4 (AC Squirrel-Cage Motor, IE3 Premium)[cite: 21] |
| Rated Motor Power (kW) | 3.0 kW (Standard)[cite: 21] |
| Output Speed / Ratio | Customizable via gearbox options (Contact for ratio details)[cite: 21] |
| Mounting Position | Universal / Foot-mounted, B5/B14 Flange Mounted[cite: 21] |
Documentation & Resources
SEW R67 Series Modular Configuration Matrix
Full-range modular assembly guide for SEW-Eurodrive Size 67 multi-stage and Size 87 single-stage helical gearboxes[cite: 21]. Review supported mechanical mountings, current IE1-IE4 motor pairings, and factory protection options:
| Gear Unit Mounting / Layout Design | Frame Size | Matched Motor Series & Powers | Optional Factory Accessories |
|---|---|---|---|
| R67 (Foot-Mounted Multi-Stage)[cite: 21] | Size 67[cite: 21] | DRN Series (IE3 Premium: 71M4 to 132M4 / 0.37 kW - 7.5 kW)[cite: 21] | /BE (Fail-Safe Disc Brake) |
| RF67 (B5 / B14 Flange Mounted)[cite: 21] | Size 67[cite: 21] | DRS Series (IE1 Standard Efficiency)[cite: 21] | /TF (PTC Thermistor Thermal Protection) |
| RX87 (Single-Stage Foot Mounted)[cite: 21] | Size 87 (RX Stage)[cite: 21] | DT / DV Series (Legacy Retrofit Motors: DT71 to DV160)[cite: 21] | /TH (Thermostat Switch Control) |
| RXF87 (Single-Stage Flange Mounted)[cite: 21] | Size 87 (RX Stage)[cite: 21] | DFT / DFV Series (ATEX Explosion-Proof Executions)[cite: 21] | /RS (Mechanical Backstop / Anti-Runback) |
| R67 / RF67 (Servomotor Adaptations)[cite: 21] | Size 67[cite: 21] | CT / CV Series (Inverter-Duty Servo Drives)[cite: 21] | /V (Forced Cooling Fan Attachment) |
Legacy SEW Motor Replacement & IE3 DRN Upgrade Guide
Obsolete SEW motor ranges (DT71, DT80, DT90, DV100, DV112, DV132, DV160) installed on R67 gearboxes can be seamlessly replaced with current IE3 Premium Efficiency DRN motors[cite: 21]. Refer to the cross-reference mapping below for 1-to-1 retrofitting:
| Legacy Motor Code (Obsolete) | Efficiency Level | Current IE3 Replacement Motor | Rated Power (kW) | Mechanical Compatibility & Retrofit Notes |
|---|---|---|---|---|
| DT71D4 / DT71C4[cite: 21] | IE1 / Standard Efficiency[cite: 21] | DRN71MS4 / DRN71M4 IE3 Upgrade[cite: 21] | 0.37 kW - 0.55 kW[cite: 21] | Direct 1-to-1 flange & shaft match on R67 gearboxes. Lower energy loss. |
| DT80K4 / DT80N4[cite: 21] | IE1 / Standard Efficiency[cite: 21] | DRN80MK4 / DRN80M4 IE3 Upgrade[cite: 21] | 0.55 kW - 0.75 kW[cite: 21] | Identical mounting dimensions; direct drop-in replacement. |
| DT90S4 / DT90L4[cite: 21] | IE1 / Standard Efficiency[cite: 21] | DRN90S4 / DRN90L4 IE3 Upgrade[cite: 21] | 1.1 kW - 1.5 kW[cite: 21] | Flange & shaft dimensions identical. Check terminal box position. |
| DV100M4 / DV100L4[cite: 21] | IE1 / IE2 Efficiency[cite: 21] | DRN100LS4 / DRN100L4 IE3 Upgrade[cite: 21] | 2.2 kW - 3.0 kW[cite: 21] | Identical shaft centerline height & mounting pattern. Standard R67 pairing[cite: 21]. |
| DV112M4 / DV132S4 / DV132M4[cite: 21] | IE1 / IE2 Efficiency[cite: 21] | DRN112M4 / DRN132S4 / DRN132M4 IE3 Upgrade[cite: 21] | 4.0 kW - 7.5 kW[cite: 21] | B5/B14 adapter compatibility preserved. Heavy multi-stage R67 pairing. |
| DV160M4[cite: 21] | IE1 / IE2 Efficiency[cite: 21] | DRN160M4 IE3 Upgrade[cite: 21] | 11.0 kW[cite: 21] | Maximum power capacity pairing for RX87 single-stage series. Drop-in replacement[cite: 21]. |
Expert Selection & Retrofit Engineering Notes
When retrofitting an existing application featuring an obsolete DT71, DT80, DT90, DV100, DV112, DV132, or DV160 motor[cite: 21], upgrading to an IE3 DRN motor ensures complete dimensional interchangeability while substantially reducing operating temperatures and energy costs. Simply send us your existing SEW serial number or nameplate code (including options like BE brake, TF thermistor, or RS backstop), and our engineering team will provide a 100% compliant replacement specification and quotation.
Core Benchmark Model Standard Configurations
- R67 DRN71M4 (0.55 kW)[cite: 21]
- R67 DRN80M4 (0.75 kW)[cite: 21]
- R67 DRN90S4 (1.1 kW)[cite: 21]
- R67 DRN90L4 (1.5 kW)[cite: 21]
- R67 DRN100LS4 (2.2 kW)[cite: 21]
- R67 DRN100L4 (3.0 kW)[cite: 21]
- R67 DRN112M4 (4.0 kW)[cite: 21]
- R67 DRN132S4 (5.5 kW)[cite: 21]
- R67 DRN132M4 (7.5 kW)[cite: 21]
- RF67 DRN90L4 (1.5 kW)[cite: 21]
- RF67 DRN100L4 (3.0 kW)[cite: 21]
- RF67 DRN112M4 (4.0 kW)[cite: 21]
- RF67 DRN132M4 (7.5 kW)[cite: 21]
- RX87 DRN100L4 (3.0 kW)[cite: 21]
- RX87 DRN132M4 (7.5 kW)[cite: 21]
- RX87 DRN160M4 (11 kW)[cite: 21]
- R67 DT90L4 (DT Replacement)[cite: 21]
- R67 DV100L4 (DV Replacement)[cite: 21]
- RF67 DV100L4 (DV Replacement)[cite: 21]
- RX87 DV160M4 (DV Replacement)[cite: 21]