SEW R97DRN180M4 Helical Inline Gearmotor
The SEW R97DRN180M4 is a heavy-duty inline helical gearmotor engineered for demanding industrial power transmission tasks requiring high mechanical power density, superior fatigue endurance, and long operating service life[cite: 22]. Featuring robust thermal stability and versatile mounting styles (foot-mounted R97/RX107, B5/B14 flange RF97/RXF107, and solid shaft)[cite: 22], it is widely deployed across heavy mining conveyors, crushing drives, agitators, and large processing plants[cite: 22].
Technical Specifications
| Model / Part Number | R97DRN180M4[cite: 22] |
|---|---|
| Brand / Manufacturer | SEW-Eurodrive[cite: 22] |
| Gear Unit Type | R Series (Helical Gear Unit, Inline Output Shaft)[cite: 22] |
| Motor Type | DRN180M4 (AC Squirrel-Cage Motor, IE3 Premium)[cite: 22] |
| Rated Motor Power (kW) | 18.5 kW (Standard)[cite: 22] |
| Output Speed / Ratio | Customizable via gearbox options (Contact for ratio details)[cite: 22] |
| Mounting Position | Universal / Foot-mounted, B5/B14 Flange Mounted[cite: 22] |
Documentation & Resources
SEW R97 Series Modular Configuration Matrix
Full-range modular assembly guide for SEW-Eurodrive Size 97 multi-stage and Size 107 single-stage helical gearboxes[cite: 22]. Review supported mechanical mountings, current IE1-IE4 motor pairings, and factory protection options:
| Gear Unit Mounting / Layout Design | Frame Size | Matched Motor Series & Powers | Optional Factory Accessories |
|---|---|---|---|
| R97 (Foot-Mounted Multi-Stage)[cite: 22] | Size 97[cite: 22] | DRN Series (IE3 Premium: 100LS4 to 225M4 / 2.2 kW - 45.0 kW)[cite: 22] | /BE (Fail-Safe Disc Brake) |
| RF97 (B5 / B14 Flange Mounted)[cite: 22] | Size 97[cite: 22] | DRS Series (IE1 Standard Efficiency)[cite: 22] | /TF (PTC Thermistor Thermal Protection) |
| RX107 (Single-Stage Foot Mounted)[cite: 22] | Size 107 (RX Stage)[cite: 22] | DV Series (Legacy Retrofit Motors: DV100 to DV225)[cite: 22] | /TH (Thermostat Switch Control) |
| RXF107 (Single-Stage Flange Mounted)[cite: 22] | Size 107 (RX Stage)[cite: 22] | DFT / DFV Series (ATEX Explosion-Proof Executions)[cite: 22] | /RS (Mechanical Backstop / Anti-Runback) |
| R97 / RF97 (Servomotor Adaptations)[cite: 22] | Size 97[cite: 22] | CT / CV Series (Inverter-Duty Servo Drives)[cite: 22] | /V (Forced Cooling Fan Attachment) |
Legacy SEW Motor Replacement & IE3 DRN Upgrade Guide
Obsolete SEW motor ranges (DV100, DV112, DV132, DV160, DV180, DV200, DV225) installed on R97 gearboxes can be seamlessly replaced with current IE3 Premium Efficiency DRN motors[cite: 22]. Refer to the cross-reference mapping below for 1-to-1 retrofitting:
| Legacy Motor Code (Obsolete) | Efficiency Level | Current IE3 Replacement Motor | Rated Power (kW) | Mechanical Compatibility & Retrofit Notes |
|---|---|---|---|---|
| DV100M4 / DV100L4[cite: 22] | IE1 / IE2 Efficiency[cite: 22] | DRN100LS4 / DRN100L4 IE3 Upgrade[cite: 22] | 2.2 kW - 3.0 kW[cite: 22] | Direct 1-to-1 flange & shaft match on R97 gearboxes. Lower energy loss. |
| DV112M4 / DV132S4[cite: 22] | IE1 / IE2 Efficiency[cite: 22] | DRN112M4 / DRN132S4 IE3 Upgrade[cite: 22] | 4.0 kW - 5.5 kW[cite: 22] | Identical mounting dimensions; direct drop-in replacement. |
| DV132M4 / DV132ML4[cite: 22] | IE1 / IE2 Efficiency[cite: 22] | DRN132M4 IE3 Upgrade[cite: 22] | 7.5 kW - 9.2 kW[cite: 22] | Flange & shaft dimensions identical. Check terminal box position. |
| DV160M4 / DV160L4[cite: 22] | IE1 / IE2 Efficiency[cite: 22] | DRN160M4 / DRN160L4 IE3 Upgrade[cite: 22] | 11.0 kW - 15.0 kW[cite: 22] | Identical shaft centerline height & mounting pattern. Standard R97 pairing[cite: 22]. |
| DV180M4 / DV180L4[cite: 22] | IE1 / IE2 Efficiency[cite: 22] | DRN180M4 / DRN180L4 IE3 Upgrade[cite: 22] | 18.5 kW - 22.0 kW[cite: 22] | B5/B14 adapter compatibility preserved. Standard R97 heavy drive unit. |
| DV200L4 / DV225S4 / DV225M4[cite: 22] | IE1 / IE2 Efficiency[cite: 22] | DRN200L4 / DRN225S4 / DRN225M4 IE3 Upgrade[cite: 22] | 30.0 kW - 45.0 kW[cite: 22] | Maximum power capacity pairing for R97/RX107 series. Heavy drive drop-in unit[cite: 22]. |
Expert Selection & Retrofit Engineering Notes
When retrofitting an existing application featuring an obsolete DV100, DV112, DV132, DV160, DV180, DV200, or DV225 motor[cite: 22], upgrading to an IE3 DRN motor ensures complete dimensional interchangeability while substantially reducing operating temperatures and energy costs. Simply send us your existing SEW serial number or nameplate code (including options like BE brake, TF thermistor, or RS backstop), and our engineering team will provide a 100% compliant replacement specification and quotation.
Core Benchmark Model Standard Configurations
- R97 DRN132M4 (7.5 kW)[cite: 22]
- R97 DRN160M4 (11 kW)[cite: 22]
- R97 DRN160L4 (15 kW)[cite: 22]
- R97 DRN180M4 (18.5 kW)[cite: 22]
- R97 DRN180L4 (22 kW)[cite: 22]
- R97 DRN200L4 (30 kW)[cite: 22]
- R97 DRN225S4 (37 kW)[cite: 22]
- R97 DRN225M4 (45 kW)[cite: 22]
- RF97 DRN160M4 (11 kW)[cite: 22]
- RF97 DRN180M4 (18.5 kW)[cite: 22]
- RF97 DRN200L4 (30 kW)[cite: 22]
- RX107 DRN160M4 (11 kW)[cite: 22]
- RX107 DRN180L4 (22 kW)[cite: 22]
- RX107 DRN225M4 (45 kW)[cite: 22]
- R97 DV160M4 (DV Replacement)[cite: 22]
- R97 DV180M4 (DV Replacement)[cite: 22]
- R97 DV200L4 (DV Replacement)[cite: 22]
- RF97 DV180L4 (DV Replacement)[cite: 22]
- RX107 DV225M4 (DV Replacement)[cite: 22]